Research Article
Impact of Solar Panel Orientation on the Integration of Solar Energy in Low-Voltage Distribution Grids
Table 4
Yearly combined PV output for all tilt and azimuth angles.
| Output (MWh) | Azimuth | -90 | -60 | -30 | 0 | 30 | 60 | 90 |
| Tilt angle | | | | | | | | 0 | 220.5 | 220.5 | 220.5 | 220.5 | 220.5 | 220.5 | 220.5 | 11.5 | 216.1 | 227.8 | 236.5 | 240.1 | 237.5 | 229.5 | 218.1 | 23 | 206.7 | 228.8 | 245.2 | 251.9 | 247.1 | 232.0 | 210.5 | 34.5 | 194.3 | 224.5 | 246.8 | 256.0 | 249.2 | 228.7 | 199.5 | 46 | 179.7 | 215.2 | 241.5 | 252.4 | 244.4 | 220.3 | 186.1 | 57.5 | 163.0 | 201.4 | 229.6 | 241.3 | 232.9 | 207.0 | 170.1 | 69 | 144.3 | 183.0 | 211.4 | 223.0 | 214.9 | 188.8 | 151.4 | 80.5 | 123.6 | 160.5 | 187.1 | 197.7 | 190.6 | 166.1 | 130.1 | 90 | 105.2 | 139.2 | 163.0 | 171.7 | 166.1 | 144.2 | 110.7 |
|
|