Research Article

Effect of Industrial Dust Deposition on Photovoltaic Module Performance: Experimental Measurements in the Tropical Region

Table 2

Temperature effect on a clean module performance.

 W/m2 W/m2 W/m2
(°C) (W) (%) (°C) (W) (%) (°C) (W) (%)

30.083.816.937.386.015.630.696.715.6
31.067.013.542.181.014.732.686.213.9
31.565.013.148.379.414.439.984.313.6
42.163.012.748.575.013.640.379.412.8
46.462.512.648.665.011.841.678.812.7