Research Article
Simple Moving Voltage Average Incremental Conductance MPPT Technique with Direct Control Method under Nonuniform Solar Irradiance Conditions
Table 3
(a) Output voltage comparisons between INC and SMVA at different
and
. (b) Output power comparisons between INC and SMVA at different
and
.
(a) |
| | | 0.001 | 0.003 | 0.005 | 0.01 | | INC | SMVA ( =) | INC | SMVA ( =) | INC | SMVA ( =) | INC | SMVA ( =) | Irr. (W/m2) | | 10 | 30 | 50 | | 10 | 30 | 50 | | 10 | 30 | 50 | | 10 | 30 | 50 |
| 600 | 388.4 | 390.4 | 390.6 | 390.3 | 386.3 | 390.6 | 390.6 | 390.6 | 383.1 | 386.1 | 386.2 | 386.2 | 378.5 | 386.1 | 386.1 | 386.1 | 800 | 396.8 | 398.5 | 398.7 | 399.1 | 394.8 | 399.0 | 399.0 | 399.0 | 391.5 | 394.7 | 394.6 | 394.6 | 386.7 | 394.6 | 394.6 | 394.6 | 1000 | 404.9 | 407.8 | 407.8 | 407.8 | 402.9 | 407.7 | 407.7 | 407.8 | 399.4 | 403.1 | 403.1 | 43.1 | 395.7 | 403.1 | 403.1 | 403.1 |
|
|
(b) |
| | | 0.001 | 0.003 | 0.005 | 0.01 | | INC | SMVA ( =) | INC | SMVA ( =) | INC | SMVA ( =) | INC | SMVA ( =) | Irr. (W/m2) | | 10 | 30 | 50 | | 10 | 30 | 50 | | 10 | 30 | 50 | | 10 | 30 | 50 |
| 600 | 2827 | 2861 | 2861 | 2861 | 2798 | 2861 | 2861 | 2861 | 2751 | 2795 | 2795 | 2795 | 2687 | 2795 | 2795 | 2795 | 800 | 2953 | 2986 | 2986 | 2986 | 2922 | 2988 | 2988 | 2988 | 2874 | 2919 | 2919 | 2919 | 2804 | 2919 | 2919 | 2919 | 1000 | 3081 | 3118 | 3118 | 3118 | 3039 | 3118 | 3118 | 3118 | 2992 | 3047 | 3047 | 3047 | 2931 | 3047 | 3047 | 3047 |
|
|