Major specifications of intermediate heat exchanger.
| Parameters | HTR50S | HTTR |
| Thermal duty (MW) | 20 | 10 | Design life time (years) | 40 | 20 | Logarithmic mean temperature difference (°C) | 76 | 101/113 | Primary flow | | | Inlet temperature (°C) | 900 | 850/950 | Outlet temperature (°C) | 670 | 387/389 | Velocity (m/s) | 12.6 | 9.3/8.1 | Secondary flow | | | Inlet temperature (°C) | 560 | 244/237 | Outlet temperature (°C) | 850 | 782/869 | Velocity (m/s) | 43.0 | 30.6/27.1 | Heat transfer tubing | | | Material | Hastelloy XR | Hastelloy XR | Outer diameter (mm) | 45.0 | 31.8 | Wall thickness (mm) | 5.0 | 3.5 | Number of tubes | 159 | 96 | Helical tube bundle | | | Number of layers | 9 | 6 | Outer diameter (m) | 2.24 | 1.31 | Inner diameter (m) | 1.20 | 0.84 | Effective heat transfer area (m2) | 500 | 215 |
|
|