Research Article

Square Wave Voltammetric Determination of Residues of Carbendazim Using a Fullerene/Multiwalled Carbon Nanotubes/Nafion/Coated Glassy Carbon Electrode

Table 4

Residual concentration of MBC determined by spectroscopy UV-Visible and square wave voltammetry measurements.

Soil samples [MBC] added (mol/L) UV-VIS Spectroscopy measurementSquare wave voltammetry measurement
Absorbance
measured
RSD
(%)
[MBC] found
(mol/L)
Recovery
(%)
Intensity
measured (A)
RSD
(%)
[MBC] found
(mol/L)
Recovery
(%)

NK15 10−50.1012.61.56 10−531.21.818 10−51.81.89 10−537.8
NK35 10−50.1191.91.60 10−532.01.841 10−51.01.92 10−538.4

.