Research Article

Selection of the Best Process Stream to Remove Ca2+ Ion Using Electrodialysis from Sugar Solution

Figure 9

Plot of limiting current density, (A·m−2), experimental current density, (A·m−2), and molar concentration of diluate tank, (mol·m−3) (shown as discrete data points), versus time for a given set of operating condition: experiment 1 (feed flow rate = 130 mL·min−1; anolyte = 100 mol·m−3 HCl; catholyte = 100 mol·m−3 NaOH; applied voltage = 4 V) [13]. Theoretically predicted values of current and concentration variation with time are shown by continuous line.