Research Article

Fracture Resistance of CAD/CAM Lithium Disilicate of Endodontically Treated Mandibular Damaged Molars Based on Different Preparation Designs

Table 2

Fracture test result (values are expressed in Newtons).

Groups
StatisticsSP0SP1CP0CP1P value

Mean1546.291634.381821.501924.05p (1) = 0.356
Minimum785.83882.381014.181164.30
Maximum2402.592462.502850.132654.20