Clinical Study

Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography (People CT Trial)

Table 5

Dose report for different scan protocols and groups.

ParameterFlashASHelical

Effective tube current (mAs)
 Group BW494 ± 81354 ± 63430 ± 99
 Group LBW511 ± 79357 ± 80454 ± 80
 Group CO508 ± 74352 ± 62405 ± 113

CTDIvol (mGy)
 Group BW2.5 ± 1.419.8 ± 15.742.0 ± 34.7
 Group LBW2.5 ± 1.317.1 ± 13.142.7 ± 17.5
 Group CO2.3 ± 1.022.2 ± 28.930.9 ± 22.9

Total DLP (mGy  cm)
 Group BW81 ± 31290 ± 198664 ± 471
 Group LBW78 ± 27273 ± 195730 ± 272
 Group CO74 ± 25271 ± 245521 ± 385

Effective dose (mSv)
 Group BW0.9 ± 0.55.4 ± 3.715.4 ± 12.1
 Group LBW0.8 ± 0.46.0 ± 4.911.8 ± 3.1
 Group CO0.8 ± 0.45.2 ± 4.59.9 ± 7.4

Note. Values are presented as mean ± standard deviation. Flash = high-pitch protocol; AS = adaptive sequence protocol; Helical = helical protocol. BW = body weight; LBW = lean body weight; CO = cardiac output; CTDIvol = CT dose index; DLP = dose length product. No significant difference was found in all radiation dose parameters between all groups (all ).