Research Article

Comparative Analysis of Classifiers for Developing an Adaptive Computer-Assisted EEG Analysis System for Diagnosing Epilepsy

Table 6

First column shows the channel label, the second column shows the initial training accuracy, and third one shows the marked correction by a neurologist and the last one shows the final accuracy.

Channel Accuracy after initial training (%) Number of epochs marked by the user Accuracy after retraining (%)

Fp1 89.0861 57 89.7390
Fp2 89.0432 57 90.0443
F3 92.5991 57 92.3307
F4 89.6807 57 90.1430
C3 91.9454 57 90.8942
C4 91.1039 57 90.9973
P3 89.3490 57 90.3629
P4 89.7354 57 89.7726
O1 89.1013 57 90.2593
O2 89.2719 57 91.0779
F7 91.9906 57 92.4641
F8 91.7540 57 91.6937
T3 93.4416 57 93.9856
T4 93.2478 57 92.9901
T5 91.3400 57 92.1312
T6 92.8583 57 92.6363
Fz 88.8938 57 89.7298
Cz 84.0064 57 85.7228
Pz 91.6708 57 92.0561
E 85.2267 57 85.5279
PG1 84.6921 57 85.2892
PG2 85.3189 57 85.3886
A1 91.6580 57 92.0482
A2 90.4476 57 90.6291
T1 84.2211 57 85.0355
T2 87.7382 57 87.7849
X1 94.3820 57 94.7490
X2 94.0092 57 94.1500
X3 86.2930 57 86.6199
X4 84.5908 57 85.6526
X5 77.4855 57 79.1122
X6 88.1346 57 89.2410
X7 80.6365 57 81.5108