Outcome comparison between all-in-one & four-in-one implant.

ParameterAll-in-one (n = 55)Four-in-one (n = 41)-value

Surgery duration (minutes)128.00 ± 36.24210.61 ± 57.540.000
X-ray findingAlpha (α) angle197.02 ± 2.7796.35 ± 5.460.476
Beta (β) angle186.62 ± 2.8086.03 ± 2.410.273
Delta (δ) angle186.33 ± 4.3686.81 ± 4.240.594
Gamma (γ) angle7.61 ± 5.477.38 ± 4.560.818
SF-12Physical score51.79 ± 7.9951.58 ± 7.960.119
Mental score58.10 ± 0.7258.06 ± 0.560.815
KSS (short form)How long can you walk (0–20)17.82 ± 2.9616.88 ± 2.760.059
Walking on an uneven surface (0–15)14.78 ± 0.9615.00 ± 0.000.131
Climbing or descending stairs (0–15)13.91 ± 3.1811.93 ± 5.710.100
Getting up from a low couch or chair without arms (0–15)14.56 ± 2.1914.49 ± 2.410.724
Running (0–20)1.04 ± 2.961.61 ± 4.090.676
Discretionary activity (0–15)14.56 ± 2.1215.00 ± 0.000.079
Total (0–100)76.67 ± 7.9874.90 ± 8.070.063
KOOSPain97.20 ± 5.0598.98 ± 1.590.082
Symptoms79.07 ± 8.6380.76 ± 5.330.184
Activities of daily living (ADL)97.31 ± 5.5198.34 ± 1.760.494
Sport and recreation69.87 ± 16.8372.80 ± 8.370.736
Quality of life88.87 ± 12.2692.93 ± 3.160.178

Note. All tests were analyzed using Mann-Whitney tests unless stated otherwise. 1, analyzed using an independent t-test. Statistically significant ().