Research Article
Biomechanical Assessment of Three Osteosynthesis Constructs by Periprosthetic Humerus Fractures
Table 1
An overview table of the results in terms of mean value and standard deviation for each of the three groups.
| | Cerclage + unicortical locking screws | Cerlcage | Plate + bicortical locking screws |
| Internal torsional stiffness (Nm/°) | 0.37 ± 0.15 | 0.51 ± 0.33 | 1.34 ± 0.16 | Mean ± SD |
| External torsional stiffness (Nm/°) | 0.57 ± 0.20 | 0.39 ± 0.24 | 1.31 ± 0.24 | Mean ± SD |
| Axial stiffness (N/mm) | 451.0 ± 41.6 | 737.5 ± 146.7 | 715.8 ± 357.7 | Mean ± SD |
|
|