Research Article
Electric Resistance Tests on Compacted Clay Material under Dynamic Load Coupled with Dry-Wet Cycling
Table 2
Testing program of dynamic load coupled with dry-wet cycling.
| Parameters | Values |
| Initial water content (%) | 14.1 | Number of drying-wetting cycles | 0, 2, 4, 9 | Amplitude of drying-wetting cycles (±%) | 0, 2, 4, 6 | Initial static deviatoric stress (kPa) | 20 | Confining pressure (kPa) | 40 | Amplitude of dynamic stress (kPa) | 40 | Loading frequency (Hz) | 5 | Number of loading cycles | 105 |
|
|