Research Article

Objective No-Reference Stereoscopic Image Quality Prediction Based on 2D Image Features and Relative Disparity

Table 6

Evaluation results comparison on MICT database.

MethodTraining
CCAAERMSEOR

Proposed, NR0.9640.2760.3360.061
Method, NR [23]0.9660.2920.3670.069
Method, FR [9]0.9450.3100.3810.065
2D quality mean, FR [34]0.7790.7150.8460.261

Testing

Proposed, NR0.9400.3390.3930.037
Method, NR [23]0.9350.3500.4210.065
Method, FR [9]0.9290.3700.4410.082
2D quality mean, FR [34]0.7580.7220.8440.208