Research Article

Improved Deflection Prediction Model for PSC Box Girder with Stay Cable System during Tensioning Phase

Table 1

Evaluation standard.

LevelQualitative descriptionQuantitative description

1No oblique cracks
2A small amount of slight oblique cracks, with the width not exceeding the limitThe crack length is less than 1/3 of the cross-sectional dimension
3There are many oblique cracks, and the width of the crack does not exceed the limitThe crack length is between 1/3 and 1/2 of the cross-sectional dimension
4A large number of oblique cracks, with the width exceeding the limitThe crack length is greater than 1/2 of the cross-sectional dimension, and the mean spacing is less than 30 cm