Research Article

Post-Fire Behavior of Modified SIFCON One-Way Plates with Waste Tire Rubber under Flexural Load: Experimental and Numerical Study

Table 5

Ultimate load, deflection, and flexural strength of all SIFCON plates.

SpecimenAt 25°CAt 600°C
First crack load (Pcr) (kN)Ultimate load (Pu) (kN)Pcr/Pu (%)First crack load (Pcr) (kN)Ultimate load (Pu) (kN)Pcr/Pu (%)

M1-F415.225.360.51421.166
M2-F4-P510.922.149.38.613.563.7
M3-F4-P1010.521.349.28.21363
M4-F4-P159.118.948.56.411.157.6