Research Article

Temperature Control and Crack Prevention Measures for Concrete Ship Locks Subjected to Prolonged Casting Interruptions

Table 2

Operating conditions for the computation.

ConditionsPlacing temperature (°C)Spacing of pipesWater temperature (°C)Silo surface insulation

Condition 1251.0 m × 1.0 m20One-time placement
Condition 2251.0 m × 1.0 m20Layered placement
Condition 3251.0 m × 1.0 m20Placing by dividing the first layer of the concrete into two blocks
Condition 4151.0 m × 1.0 m15Insulate the floor; equivalent heat release coefficient is 2.92 kJ/(m2 h °C)