Research Article

Comparison of the Time Domain Windows Specified in the ISO 18431 Standards Used to Estimate Modal Parameters in Steel Plates

Table 2

Percentage error (%) of mode estimation with respect to numerical model.

Vibrational
mode
Hanning
Flat-top
Rectangular

First bending 0.77040.1887 0.0472
First torsion0.05960.0596 0.4024
Second torsion0.47550.2038 0.2717
Second bending3.47563.10983.2927